1. Equipment acceptance requirements
(1) The random file is complete.China Best elevator manufacturers
(2) Equipment parts and components should be consistent with the contents of the packing list.
(3) There should be no obvious damage to the appearance of the equipment.
2. Acceptance requirements for civil construction handover inspection
(1) The internal and shaft civil (steel frame) structure and layout of the machine room (if any) must meet the requirements of the elevator civil layout drawing. The minimum clearance size of the hoistway should be consistent with the requirements of the civil layout. The wall of the hoistway should be vertical, and the allowable deviation of the minimum headroom size using the plumb method is: 0 ~ +25mm for hoistway with elevator travel height ≤ 30m; 0 ~ +35mm for hoistway with elevator travel height ≤ 60m; 60m< elevator travel The hoistway with height ≤90m, 0~ +50mm; the hoistway with elevator travel height >90m, meets the requirements of the civil construction plan.
(2) When there is a space that can be reached by personnel under the pit of the hoistway, and there is no safety gear device on the counterweight (or counterweight), the counterweight buffer must be able to be installed (or under the counterweight operating area). ) Extends to the solid pile on the solid ground.
(3) Before the elevator is installed, all reserved holes in the hall doors must be provided with a safety enclosure (safety protection door) with a height of not less than 1200mm, and sufficient strength shall be ensured. The lower part of the protective enclosure shall have a height of not less than 100mm. The skirting board should be opened from left to right, not up and down.For example, the safety protection enclosure should extend upward from the bottom surface of the reserved hole of the landing door to a height of not less than 1200mm. It should be made of wood or metal materials, and it should be a removable structure. In order to prevent other personnel from removing or overturning it, It should be connected to the building. The material, structure, and strength of the safety enclosure
shall comply with the relevant requirements of the "Technical Code for Safety of Construction at Heights" JGJ 80- -2016.
(4) When the distance between two adjacent door sills is greater than 11m, a hoistway safety door must be installed in between. The hoistway
safety door is strictly prohibited to open into the hoistway, and must be equipped with an electrical safety device that can only operate when the safety door is closed. When there are car safety doors for mutual rescue between adjacent cars, this paragraph may not be implemented.
(5) There should be good anti-seepage and anti-leakage protection in the machine room and pit, and there should be no water in the pit.
(6) The main power supply should adopt the TN-S system. The switch should be able to cut off the maximum current under normal use of the elevator. For elevators with machine room, the switch should be easily accessible from the entrance of the machine room. For elevators with machine room, the switch should be set outside the hoistway. Places that are convenient for the staff to approach, and should have the necessary
safety protection. The grounding resistance value of the grounding device in the equipment room should not be greater than 40.
(7) Fixed electrical lighting should be provided in the machine room (if any), the ground illuminance should not be less than 2001x, and a switch or similar device should be provided at an appropriate height near the population to control the lighting power supply.
(8) Permanent electric lighting should be installed in the hoistway. The lighting voltage of the hoistway should be 36V safe voltage. The illumination in the hoistway should not be less than 50k. The highest point and the lowest M05m of the hoistway should be equipped with a separate control switch in the engine room and the pit.
(9) The floor of the pit under the car buffer support should be able to withstand full Multiple parallel and relative elevators should be mentioned
(10) Each floor should have the final completion site and benchmark mark and benchmark mark.

Related Products

Passenger Elevator

Passenger Elevator

Tenau passenger elevators with small machine room have improved their performance by reducing area o...

Panoramic elevator

Panoramic elevator

Elegant structure with limitless scenic views Tenau sightseeing elevator adheres to the design prin...

Freight Elevator

Freight Elevator

Considerate designing This elevator is specifically designed for the transportation of cargoes, wit...

Car Elevator

Car Elevator

In the modern city, there are more and more cars. To solve the difficulty of parking, TENAU uses its...

Hospital Elevator

Hospital Elevator

High safety standard with sincere care Tenau high-quality medical elevator is developed on basis of...

Home Elevator

Home Elevator

Let’s construct a happy and harmonious life!Machine roomless intensive design, "electric home applia...

Escalator Summary

Escalator Summary

Urban flavor, charm scene TENAU serial escalators fully apply novel materials and advanced domestic...

Moving Walk Summary

Moving Walk Summary

As easy as in smooth ground, the everlasting popular design & qualityTENAU moving walk elevates ...

Passenger Elevator

Passenger Elevator

Professional Machine roomless passenger elevators companyTenau machine roomless passenger elevators ...

Panoramic Elevator

Panoramic Elevator

ATTRACTIVE & POPULAR TENAU Elevator sends out leaders' demeanor.It comes from innovative streng...

Freight Elevator

Freight Elevator

Vertical cargo transportation TENAU machine roomless freight elevators are in compact structure, ad...

Car Elevator

Car Elevator

In the modern city, there are more and more cars. To solve the difficulty of parking, TENAU uses its...

3D PANORAMA

Contact Us

*We respect your confidentiality and all information are protected.